<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Materials physics and mechanics</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Механика и физика материалов</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">1605-8119</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">11</article-id>
      <title-group>
        <article-title>Fatigue of commercially pure titanium dental implants</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Fatigue of commercially pure titanium dental implants</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Pasang</surname>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Ramezani</surname>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Prygoski</surname>
          </name>
          <xref ref-type="aff" rid="aff3"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Wanhill</surname>
          </name>
          <xref ref-type="aff" rid="aff4"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Byrnes</surname>
          </name>
          <xref ref-type="aff" rid="aff5"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kamiya</surname>
          </name>
          <xref ref-type="aff" rid="aff6"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Tanaka</surname>
          </name>
          <xref ref-type="aff" rid="aff7"/>
        </contrib>
      </contrib-group>
      <aff id="aff1">Auckland University of Technology</aff>
      <aff id="aff2">Tarbiat Modares University</aff>
      <aff id="aff3">University of Notre Dame</aff>
      <aff id="aff4">National Aerospace Laboratory NLR</aff>
      <aff id="aff5">Airframes &amp; Engine Division, Platform Sciences Laboratory, Defence Science &amp; Technology Organisation (DSTO)</aff>
      <aff id="aff6">Akita University</aff>
      <aff id="aff7">kita University Hospital</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2016-06-28">
        <day>28</day>
        <month>06</month>
        <year>2016</year>
      </pub-date>
      <volume>27</volume>
      <issue>1</issue>
      <fpage>79</fpage>
      <lpage>89</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://mpm.spbstu.ru/userfiles/files/MPM127_10_ramezani.pdf"/>
      <abstract xml:lang="en">
        <p>Failure of two commercially pure titanium dental implants was analysed. The implants fractured at the abutments after only three years use. One abutment failed at the junction of the threaded and unthreaded areas, the other failed within the threaded area. Both failures were by reversed bending fatigue, whereby fatigue cracks began from relatively coarse machining marks on the abutments. The final fracture areas were less than 10 % of the total fracture surfaces, indicating that the abutments had not been abnormally loaded. However, bone resorption would have increased the abutment bending stresses by causing an increased moment arm of the acting forces and misalignment of the abutments in the maxilla. The effect of misalignment was investigated by finite element modelling, which showed that even a slight misalignment could double the bending stresses. This unanticipated large effect, combined with the coarse machining marks, explains the premature failure of the implants.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>dental implant</kwd>
        <kwd>fatigue</kwd>
        <kwd>finite element simulation</kwd>
        <kwd>metallography</kwd>
        <kwd>titanium</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>