<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Materials physics and mechanics</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Механика и физика материалов</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">1605-8119</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">10</article-id>
      <article-id pub-id-type="doi">10.18720/MPM.3612018_10</article-id>
      <title-group>
        <article-title>Investigation of the possibility of improving the X-ray fluorescence spectrometer analytical characteristics due to using the superfine beryllium foils</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Investigation of the possibility of improving the X-ray fluorescence spectrometer analytical characteristics due to using the superfine beryllium foils</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Mishin</surname>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Shishov</surname>
          </name>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kiselev</surname>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Matsinkevich</surname>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Rudnev</surname>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Bukin</surname>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
      </contrib-group>
      <aff id="aff1">Peter the Great St. Petersburg Polytechnic University</aff>
      <aff id="aff2">Spectron Ltd.</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2018-04-28">
        <day>28</day>
        <month>04</month>
        <year>2018</year>
      </pub-date>
      <volume>36</volume>
      <issue>1</issue>
      <fpage>92</fpage>
      <lpage>99</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://mpm.spbstu.ru/userfiles/files/MPM136_10_mishin.pdf"/>
      <abstract xml:lang="en">
        <p>Studies were made the possibilities of increasing the wave-dispersive X-rayfluorescence spectrometer analytical characteristics due to using the superfine beryllium foils5-8 μm thick in the X-ray detector. Investigations by the example of spectrometerSPECTROSCAN MAX-GVM showed that the decrease of foil thickness can significantlyincrease the spectrometer analytical characteristics in the determination of light elements(sodium and magnesium). It has been established what count rate increases 8.5 times for sodium and 4.6 times for magnesium due to using the X-ray windows with thickness of 5 and8 μm. Reducing of X-ray window thickness can be achieved by using beryllium foils obtained by severe cold plastic deformation. Such foils have increased plasticity, which allowsreducing the X-ray window thickness without spectrometer reliability decreasing.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>x-ray spectroscopy analysis</kwd>
        <kwd>spectrometer</kwd>
        <kwd>x-ray detector</kwd>
        <kwd>thin beryllium foils</kwd>
        <kwd>x-rays transmission</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
